Sunny Boy Control Light

Electrical Data  
Grid Voltage 90 to 260V, 50 to 60 Hz
Power consumption in operation
(dependent on the number of monitored
Sunny Boy inverters)
4 to 6 W
Power consumption in stand-by 3 W
General Data  
Carrier Frequency for Powerline
Communication
132.45 kHz
Display 4 x 16 characters Liquid Crystal Display
Ambient temperature 32° F to 104° F or 0° C to 40° C
Protection class IP 40
Fuse automatic overload protection, 365V/90mA
CE-conformity Yes
Dimentions 229 x 126 x 46 mm
Weight (approx.) 1250 g
Data Processing  
Max number of Sunny Boys 20
Daily energy value stored 200 days
Measurement data storage -
Measurement data storage capacity -
Interfaces  
Sunny Boy =COM1
Powerline
PC =COM2
RS 232
AUX =COM3
-
Switching contacts -
Analog Input Channels -
Digital Input Channels -
Digital Output Channels -
Monitoring  
Event History Yes
Warnings and Failures Yes
Beeper None
Modem Operation3 Yes
Fax Support3 Yes
External Displays Yes
Variable channels4 None
Monitoring Channels None
Extras  
Integrated RTC None
1 optional
2 6 input cnahhels freely configurable (e.g. for radiation measurement) and 2 channels for Pt 100 temperature measurement
3 external modem required